Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 396
Filtrar
1.
Catheter Cardiovasc Interv ; 103(6): 1004-1014, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38577939

RESUMO

INTRODUCTION: Bicuspid aortic valve (BAV) stenosis is a complex anatomical scenario for transcatheter aortic valve implantation (TAVI). Favorable short-term clinical outcomes have been reported with TAVI in this setting, but long-term data are scarce. METHODS: We retrospectively included, in a single-center registry, patients with BAV stenosis who underwent TAVI before 2020. We compared patients treated with self-expanding valves (SEV) versus balloon-expandable valves (BEV). The primary endpoint was a composite of all-cause mortality, stroke and need for aortic valve (AV) reintervention at 3 years. Secondary endpoints included each component of the primary endpoint, cardiovascular mortality, permanent pacemaker implantation (PPI) rate, mean gradient and ≥moderate paravalvular leak (PVL) rate. RESULTS: A total of 150 consecutive patients (SEV = 83, BEV = 67) were included. No significant differences were reported between SEV and BEV groups for the primary composite endpoint (SEV 35.9% vs. BEV 32%, p = 0.66), neither for clinical secondary endpoints (all-cause mortality SEV 28.1% vs. BEV 28%, p = 0.988; cardiovascular mortality SEV 14.1% vs. BEV 20%, p = 0.399; stroke SEV 12.5% vs. BEV 6%, p = 0.342; need for AV reintervention SEV 0% vs. BEV 0%; PPI SEV 28.1% vs. BEV 24%, p = 0.620). A lower mean gradient persisted up to 3 years in the SEV group (SEV 8.8 ± 3.8 mmHg vs. BEV 10.7 ± 3.2 mmHg, p = 0.063), while no significant difference was found in the rate of ≥ moderate PVL (SEV 3/30 vs. BEV 0/25, p = 0.242). CONCLUSIONS: In this single center registry, we observed favorable 3-year clinical outcomes in nonselected BAV patients treated with different generation devices, without significant differences between patients receiving SEV or BEV.


Assuntos
Estenose da Valva Aórtica , Valvuloplastia com Balão , Doença da Válvula Aórtica Bicúspide , Próteses Valvulares Cardíacas , Desenho de Prótese , Sistema de Registros , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Substituição da Valva Aórtica Transcateter/mortalidade , Masculino , Feminino , Estudos Retrospectivos , Resultado do Tratamento , Doença da Válvula Aórtica Bicúspide/fisiopatologia , Doença da Válvula Aórtica Bicúspide/diagnóstico por imagem , Doença da Válvula Aórtica Bicúspide/mortalidade , Doença da Válvula Aórtica Bicúspide/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/mortalidade , Fatores de Tempo , Idoso , Valvuloplastia com Balão/efeitos adversos , Valvuloplastia com Balão/mortalidade , Idoso de 80 Anos ou mais , Fatores de Risco , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Valva Aórtica/fisiopatologia , Valva Aórtica/anormalidades , Recuperação de Função Fisiológica , Hemodinâmica , Medição de Risco
2.
Catheter Cardiovasc Interv ; 103(6): 1035-1041, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38545668

RESUMO

A distinctive complication with balloon-expandable (BE) THV platforms such as the Edwards Sapien (Edwards Lifescience) is the possibility of balloon rupture during THV deployment. Balloon rupture is a rare occurrence that can result in stroke due to fragment embolism, incomplete THV expansion, and/or vascular injury upon retrieval of the balloon. Careful evaluation of preoperative computed tomography is essential to identify high-risk cases. While annular and left ventricular outflow tract (LVOT) calcification are widely acknowledged as common risks for balloon injury, it's essential to note that balloon injury can manifest at various anatomical sites. In this review, we discuss the mechanism behind balloon rupture, methods to identify cases at a heightened risk of balloon injury, approaches to mitigate the risk of rupture, and percutaneous retrieval strategies.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Valvuloplastia com Balão , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Resultado do Tratamento , Valvuloplastia com Balão/efeitos adversos , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Desenho de Prótese , Remoção de Dispositivo , Falha de Equipamento , Cateteres Cardíacos
3.
JACC Cardiovasc Interv ; 17(8): 1032-1044, 2024 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-38456883

RESUMO

BACKGROUND: The fifth-generation SAPIEN 3 Ultra Resilia valve (S3UR) incorporates several design changes as compared with its predecessors, the SAPIEN 3 (S3) and SAPIEN 3 Ultra (S3U) valves, including bovine leaflets treated with a novel process intended to reduce structural valve deterioration via calcification, as well as a taller external skirt on the 29-mm valve size to reduce paravalvular leak (PVL). The clinical performance of S3UR compared with S3 and S3U in a large patient population has not been previously reported. OBJECTIVES: The aim of this study was to compare S3UR to S3/S3U for procedural, in-hospital, and 30-day clinical and echocardiographic outcomes after transcatheter aortic valve replacement (TAVR). METHODS: Patients enrolled in the STS/ACC TVT (Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy) Registry between January 1, 2021, and June 30, 2023, who underwent TAVR with S3UR or S3U/S3 valve platforms were propensity-matched and evaluated for procedural, in-hospital, and 30-day clinical and echocardiographic outcomes. RESULTS: 10,314 S3UR patients were propensity matched with 10,314 patients among 150,539 S3U/S3 patients. At 30 days, there were no statistically significant differences in death, stroke, or bleeding, but a numerically higher hospital readmission rate in the S3UR cohort (8.5% vs 7.7%; P = 0.04). At discharge, S3UR patients exhibited significantly lower mean gradients (9.2 ± 4.6 mm Hg vs 12.0 ± 5.7 mm Hg; P < 0.0001) and larger aortic valve area (2.1 ± 0.7 cm2 vs 1.9 ± 0.6 cm2; P < 0.0001) than patients treated with S3/S3U. The 29-mm valve size exhibited significant reduction in mild PVL (5.3% vs 9.4%; P < 0.0001). CONCLUSIONS: S3UR TAVR is associated with lower mean gradients and lower rates of PVL than earlier generations of balloon expandable transcatheter heart valve platforms.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Valvuloplastia com Balão , Próteses Valvulares Cardíacas , Desenho de Prótese , Recuperação de Função Fisiológica , Sistema de Registros , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/instrumentação , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Feminino , Resultado do Tratamento , Masculino , Estados Unidos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/fisiopatologia , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Idoso , Idoso de 80 Anos ou mais , Fatores de Tempo , Valvuloplastia com Balão/efeitos adversos , Fatores de Risco , Hemodinâmica , Complicações Pós-Operatórias/etiologia , Medição de Risco , Estudos Retrospectivos
4.
Am Heart J ; 270: 13-22, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38253304

RESUMO

BACKGROUND: Safety and feasibility of transcatheter aortic valve replacement (TAVR) without balloon aortic valvuloplasty (BAV) using the SAPIEN 3 balloon-expandable device has been previously demonstrated. The impact on long-term valve hemodynamic performances and outcomes remains however unknown. We evaluate long-term clinical and hemodynamic results according to the implant strategy (direct TAVR vs BAV pre-TAVR) in patients included in the DIRECTAVI randomized trial (NCT02729519). METHODS: Clinical and echocardiographic follow-up until January 2023 was performed for all patients included in the DIRECTAVI trial since 2016 (n = 228). The primary endpoint was incidence of moderate/severe hemodynamic valve deterioration (HVD), according to the Valve Academic Research defined Consortium-3 criteria (increase in mean gradient ≥10 mmHg resulting in a final mean gradient ≥20 mmHg, or new/worsening aortic regurgitation of 1 grade resulting in ≥ moderate aortic regurgitation). RESULTS: Median follow-up was 3.8 (2.2-4.7) years. Mean age at follow-up was 87 ± 6.7 years. No difference in incidence of HVD in the direct implantation group compared to the BAV group was found (incidence of 1.97 per 100 person-years and 1.45 per 100 person-years, respectively, P = 0.6). Prevalence of predicted prothesis-patient mismatch was low (n = 13 [11.4%] in the direct TAVR group vs n = 15 [13.2%] in BAV group) and similar between both groups (P = .7). Major outcomes including death, stroke, hospitalization for heart failure and pacemaker implantation were similar between both groups, (P = .4, P = .7, P = .3, and P = .3 respectively). CONCLUSION: Direct implantation of the balloon-expandable device in TAVR was not associated with an increased risk of moderate/severe HVD or major outcomes up to 6-year follow-up. These results guarantee wide use of direct balloon-expandable valve implantation, when feasible. CLINICAL TRIALS REGISTRATION NUMBER: NCT05140317.


Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica , Valvuloplastia com Balão , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Idoso de 80 Anos ou mais , Substituição da Valva Aórtica Transcateter/métodos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Seguimentos , Insuficiência da Valva Aórtica/cirurgia , Resultado do Tratamento , Fatores de Tempo , Desenho de Prótese , Valvuloplastia com Balão/efeitos adversos
6.
Catheter Cardiovasc Interv ; 102(6): 1101-1104, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37855219

RESUMO

Balloon aortic valvuloplasty (BAV) is preferred by most centers over surgery for the treatment of congenital valve stenosis, due to its less invasive nature and faster recovery time. A variety of techniques have been employed to induce a transient cardiac standstill and reduce longitudinal balloon displacement during valve dilatation. Rapid right ventricular (RV) pacing is an effective method to stabilize the balloon during aortic valvuloplasty and it is regularly used in older children and adults. Despite the evidence of its feasibility and efficacy, its use in neonates and infants is still not widespread globally as it is associated with certain drawbacks in this population. We report the use of a new technique to achieve balloon stabilization during BAV in neonates and infants. Four patients with severe congenital aortic valve stenosis were treated with percutaneous BAV using rapid transesophageal atrial pacing. Rapid atrial pacing was performed in asynchronous modality at a rate which resulted in a drop of the systemic arterial pressure by 50%. The balloon was inflated only after the set pacing rate was reached. The pacing was continued until the balloon was completely deflated. No ventricular arrhythmia occurred. Fluoroscopy time was not influenced by transesophageal pacing. Mild aortic regurgitation developed in only one case. Rapid transesophageal atrial pacing was safe and allowed a significant relief of left ventricular obstruction while minimizing aortic regurgitation. Compared to RV pacing, it does not require additional vascular access. Moreover, transesophageal pacing is not at risk of cardiac or vascular perforation and ventricular arrhythmias.


Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica , Fibrilação Atrial , Valvuloplastia com Balão , Criança , Recém-Nascido , Humanos , Lactente , Resultado do Tratamento , Valvuloplastia com Balão/efeitos adversos , Valvuloplastia com Balão/métodos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia
7.
Interv Cardiol Clin ; 12(4): 539-554, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37673498

RESUMO

Percutaneous structural interventions have a major impact on the morbidity, mortality, and quality of life of patients by providing a lower-risk alternative to cardiac surgery. However, renal disease has a significant impact on outcomes of these interventions. This review explores the incidence, outcomes, pathophysiology, and preventative measures of acute kidney injury and chronic kidney disease on transcatheter aortic valve replacement, transcatheter mitral valve repair, and percutaneous balloon mitral valvuloplasty. Given the expanding indications for percutaneous structural interventions, further research is needed to identify ideal patients with chronic kidney disease or end-stage renal disease who would benefit from intervention.


Assuntos
Injúria Renal Aguda , Valvuloplastia com Balão , Insuficiência Renal Crônica , Substituição da Valva Aórtica Transcateter , Humanos , Injúria Renal Aguda/epidemiologia , Injúria Renal Aguda/fisiopatologia , Injúria Renal Aguda/prevenção & controle , Injúria Renal Aguda/cirurgia , Valvuloplastia com Balão/efeitos adversos , Incidência , Valva Mitral/cirurgia , Insuficiência Renal Crônica/epidemiologia , Insuficiência Renal Crônica/fisiopatologia , Insuficiência Renal Crônica/prevenção & controle , Insuficiência Renal Crônica/cirurgia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Medição de Risco
8.
Curr Probl Cardiol ; 48(12): 102021, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37544629

RESUMO

Echocardiography is an important diagnostic imaging modality in recognizing rheumatic heart disease, a chronic sequelae of acute rheumatic fever. Left-sided heart valves, especially the mitral valve is typically affected, with stenosis or regurgitation as a consequence. Although assessment of valve area by 2D planimetry is the reference method for mitral stenosis severity, 3D planimetry provides more accurate measurement and diagnostic value. Careful selection of patients in terms of echocardiographic criteria is essential to ensure safety and success of the intervention and better long-term outcomes. Several echocardiographic scores based upon mitral valve mobility, thickening, calcification, and subvalvular thickening are developed to assess mitral valve anatomy and the feasibility of percutaneous mitral commissurotomy. 3D transesophageal echocardiography (TEE) provides detailed information of the mitral anatomy (commissural fusions, and subvalvular apparatus) before intervention. In addition, 3D TEE planimetry provides a more accurate measurement of the valve area compared with 2D echocardiography. Generally, huge annular calcification and lack of commissural fusion are unfavorable echocardiographic markers that increase the risk of complications and preclude the feasibility of percutaneous balloon mitral valvuloplasty. More contemporary prospective echocardiography research studies on patients with RHD from low- and middle-income countries are needed.


Assuntos
Valvuloplastia com Balão , Calcinose , Estenose da Valva Mitral , Cardiopatia Reumática , Humanos , Cardiopatia Reumática/diagnóstico por imagem , Cardiopatia Reumática/terapia , Estudos Prospectivos , Ecocardiografia/métodos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Estenose da Valva Mitral/diagnóstico por imagem , Estenose da Valva Mitral/terapia , Calcinose/diagnóstico por imagem , Calcinose/terapia , Valvuloplastia com Balão/efeitos adversos
9.
BMC Pediatr ; 23(1): 337, 2023 07 04.
Artigo em Inglês | MEDLINE | ID: mdl-37400786

RESUMO

BACKGROUND: Pulmonary stenosis (PS) is a congenital heart diseases (CHDs) with a spectrum of stenosis. Monochorionic (MC) twins are at increased risk of CHDs, especially acquired CHDs in twin-twin transfusion syndrome (TTTS). PS/Pulmonary atresia (PA) is a rare coincidence with TTTS. MC twin pregnancies have increased in last decades due to increasing in maternal age and extensive use of assisted reproductive technologies. Therefore, attention to this group is important for heart abnormalities, especially in twins with TTTS. Multiple cardiac abnormalities in MC twins with TTTS are to be expected due to cardiac hemodynamic changes and may be eliminated by Fetoscopic laser photocoagulation treatment. Prenatal diagnosis of PS is necessary given the importance of treatment after birth. CASE PRESENTATION: We here present a case of coexistence of TTTS with PS in a growth restricted recipient twin who successfully treated with balloon pulmonary valvuloplasty in neonatal period. Also, we detected infundibular PS after valvuloplasty that treated with medical therapy (propranolol). CONCLUSIONS: It is important to detect acquired cardiac abnormalities in MC twins with TTTS, and follow them up after birth to determine the need of intervention in neonatal period.


Assuntos
Valvuloplastia com Balão , Transfusão Feto-Fetal , Cardiopatias Congênitas , Estenose da Valva Pulmonar , Gravidez , Recém-Nascido , Feminino , Humanos , Transfusão Feto-Fetal/complicações , Transfusão Feto-Fetal/diagnóstico , Transfusão Feto-Fetal/terapia , Valvuloplastia com Balão/efeitos adversos , Gêmeos , Estenose da Valva Pulmonar/etiologia , Estenose da Valva Pulmonar/cirurgia , Parto , Cardiopatias Congênitas/complicações
10.
J Am Heart Assoc ; 12(12): e028837, 2023 06 20.
Artigo em Inglês | MEDLINE | ID: mdl-37301755

RESUMO

Background The goal of this study was to evaluate long-term results of percutaneous balloon valvuloplasty (BVPL) used exclusively for initial management of congenital aortic stenosis in children. Methods and Results A total of 409 consecutive pediatric patients (134 newborns, 275 older patients) who underwent BVPL as initial treatment of aortic stenosis in a single nationwide pediatric center were subjected to a retrospective follow-up study. The resulting follow-up time reached a median of 18.5 (interquartile range, 12.2-25.1) years. Successful BVPL was defined by residual Doppler gradient <70/40 (systolic/mean) mm Hg. The primary end point was death; secondary end points included any valve reintervention, balloon revalvuloplasty, any aortic valve surgery, and aortic valve replacement, respectively. BVPL effectively reduced the peak and mean gradient both immediately and at the latest follow-up (P<0.001). There was significant procedure-related progression of aortic insufficiency (P<0.001). Higher aortic annulus z score was predictive for severe aortic regurgitation (P<0.05) and lower z score for insufficient gradient reduction (P<0.05). The actuarial probability of survival/survival free from any valve reintervention was 89.9%/59.9%, 85.9%/35.2%, and 82.0%/26.7% at 10, 20, and 30 years after first BVPL, respectively. Left ventricular dysfunction or arterial duct dependency as the indication for BVPL was predictive of both worse survival and survival free from any reintervention (P<0.001). Lower aortic annulus z score and lower balloon-to-annulus ratio were predictive of a need for revalvuloplasty (P<0.001). Conclusions Percutaneous BVPL provides good initial palliation. In patients with hypoplastic annuli and left ventricular or mitral valve comorbidity, the results are less favorable.


Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica , Valvuloplastia com Balão , Cardiopatias Congênitas , Criança , Humanos , Recém-Nascido , Lactente , Seguimentos , Valvuloplastia com Balão/efeitos adversos , Estudos Retrospectivos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/congênito , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/cirurgia , Resultado do Tratamento
11.
Cardiovasc Revasc Med ; 55: 1-7, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37208215

RESUMO

BACKGROUND: Severe Aortic stenosis (AS) complicated by cardiogenic shock (CS) represents a grave clinical condition with limited treatment options. Evidence from small observation studies favors that Transcatheter Aortic Valve Replacement (TAVR) might be a feasible option in these patients in contrast to emergent Balloon Aortic Valvuloplasty (BAV) which is associated with very high short and long-term mortality. METHODS: 11,405 hospitalizations with severe AS complicated by CS between 2016 and 2020 were identified using the National Inpatient Sample (NIS) Database, and patients were then stratified according to whether they received TAVR or BAV. Propensity-score matching was used to account for differences in the baseline characteristics. Primary and secondary outcomes were then compared between 3485 hospitalizations in direct TAVR group and with 3485 matched hospitalizations in the BAV group. The primary outcome was a composite of all-cause in-hospital death, acute cerebrovascular accident (CVA), and myocardial infarction (MI). Secondary outcomes and safety outcomes were also compared between the two groups. RESULTS: TAVR was associated with fewer primary outcomes events as compared to BAV {36.8 % vs 56.8 %, aOR (95%CI) = 0.38(0.30-0.47)}, due to fewer all-cause in-hospital deaths {17.8 % vs 38.9 %, aOR (95%CI) =0.34 (0.26-0.43)} and MI {12.3 % vs 32.4 %, aOR (95%CI) = 0.29 (0.22-0.39)}. TAVR was associated with higher rates of acute CVA {6.17 % vs 3.44 %, aOR (95%CI) = 1.84 (1.08-3.21)} and pacemaker implantation post procedure {11.9 % vs 6.03 %, aOR (95%CI) = 2.10 (1.41-3.18)}. CONCLUSION: Direct TAVR in shock and severe Aortic stenosis is a better strategy than rescue Balloon aortic valvotomy.


Assuntos
Estenose da Valva Aórtica , Valvuloplastia com Balão , Infarto do Miocárdio , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Pacientes Internados , Choque Cardiogênico/diagnóstico , Choque Cardiogênico/etiologia , Choque Cardiogênico/terapia , Mortalidade Hospitalar , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Valvuloplastia com Balão/efeitos adversos , Infarto do Miocárdio/cirurgia
13.
Heart Vessels ; 38(7): 957-963, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36781429

RESUMO

Management of high-risk patients with severe aortic stenosis (AS) is a challenging issue. The prognosis of patients with AS presenting with therapy-refractory pulmonary edema (RPE) or cardiogenic shock (CS) remains poor. The purpose of this study was to assess the 30-day mortality of rescue percutaneous balloon aortic valvuloplasty (PBAV) in AS patients presenting with RPE or CS in a community-based hospital without on-site heart surgery. From January 2016 to February 2019, we identified consecutively admitted patients with CS or RPE related to severe AS who underwent emergent PBAV. The primary end point was 30-day mortality. Secondary end points included procedural adverse events according to the Valve Academic Research Consortium (VARC)-2 criteria and predictive factors of the primary end point. We identified 51 patients with either CS (n = 22) or RPE (n = 29). All PBAV procedures were successful with a significant reduction in peak-to-peak gradient (median, [IQR] from 40 [27] mmHg to 15 [20] mmHg, p < 0.001). No procedural deaths occurred, while adverse events included stroke (4%), minor vascular complications (6%), minor (4%) and major bleedings (4%), and no life-threatening bleeding. Overall, 15 deaths (29%) were noted at 30 days after PBAV, while 53% of the surviving patients were successfully bridged to transcatheter aortic valve implantation (TAVI). 30-day mortality was significantly higher in the CS group compared to the RPE (n = 10 (45%) vs n = 5 (7%), p = 0.029), and was significantly associated with the presence of acute kidney injury (OR 9.09, 95% CI 2.13-38.77, p = 0.003) and elevated pulmonary artery systolic pressure (OR 1.06, 95% CI 1.0-1.12, p = 0.047). Rescue PBAV in patients with severe AS presenting with RPE or CS is a feasible and effective therapeutic option, even in a community-based hospital without on-site heart surgery. Rescue PBAV resulted in 30-day survival of more than 70%, with more than half of the surviving patients having been successfully bridged to TAVI.


Assuntos
Estenose da Valva Aórtica , Valvuloplastia com Balão , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Valvuloplastia com Balão/efeitos adversos , Prognóstico , Choque Cardiogênico , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia
14.
Vasc Health Risk Manag ; 19: 13-20, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36687312

RESUMO

Background: Percutaneous balloon mitral valvuloplasty (PBMV) is considered the most suitable option for managing symptomatic severe mitral valve stenosis (MS) during pregnancy with favorable anatomy. We do not know the best time to perform PBMV during pregnancy to achieve the best maternal and fetal outcomes. Therefore, we conducted this study to clarify the best procedure timing. Methods: This prospective, observational, single-center study involved 44 pregnant patients suffering from symptomatic MS who underwent PBMV from May 2017 to May 2020. A detailed history is taken, full clinical examination, laboratory assessment, 2 D echocardiography, and follow-up during the hospital stay and monthly until labor. Results: We found that the mean mitral valve area (MVA) had significantly increased from 1.12 ± 0.24 to 2.09 ± 0.46 cm2 (P < 0.001). The mean pressure gradient across the mitral valve reduced from 17.22 ± 5.55 to 8.94 ± 3.75 mmHg (P < 0.001). The procedures were successful in 91% of the patients. Regarding obstetric outcomes, the incidence of preterm labor, fetal death, and composite adverse outcomes was significantly lower in patients who had the procedure during the second trimester than those who had the procedure during the third trimester. All preterm deliveries and intrauterine fetal deaths occurred at least 21 days after PBMV. The patients showed a statistically significant improvement in NYHA functional classification. Conclusion: We can conclude that PBMV performed in pregnant patients is an effective and safe treatment modality, and we observed better obstetric outcomes achieved with early intervention during the second trimester.


Assuntos
Valvuloplastia com Balão , Estenose da Valva Mitral , Gravidez , Feminino , Recém-Nascido , Humanos , Estudos Prospectivos , Valvuloplastia com Balão/efeitos adversos , Valvuloplastia com Balão/métodos , Valva Mitral/diagnóstico por imagem , Estenose da Valva Mitral/diagnóstico por imagem , Estenose da Valva Mitral/terapia , Ecocardiografia/métodos
15.
Kardiol Pol ; 81(4): 366-372, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36648223

RESUMO

BACKGROUND: Long-term outcomes of balloon aortic valvuloplasty (BAV) in patients with severe symptomatic aortic stenosis (AS) are poor, and this procedure needs to be repeated in selected cases. AIMS: We aimed to investigate the safety and efficacy of repeated BAV (reBAV). METHODS: We included consecutive patients who underwent reBAV in three Polish centers between 2010 and 2019. Baseline clinical, echocardiographic, procedural, and outcome data were analyzed. RESULTS: Thirty-five patients (median age 81.5 years, 57.1% women) who underwent reBAV were enrolled. In 42.9% of the patients, index BAV was considered a palliative treatment, and in 54.3% a bridge to definitive treatment. Index BAV decreased peak aortic valve gradient (pAVG) from a median of 78.0 mm Hg to 46.0 mm Hg (P <0.001). After a mean of 255.8 days, reBAV was performed. In most cases (71.4%), the reason for reBAV was the worsening of heart failure symptoms and in 54.3% of patients, reBAV was still considered a palliative option. A decrease in pAVG max from a median of 73.0 mm Hg to 45.0 mm Hg (P <0.001), comparable to index BAV, was observed. The frequency of complications were numerically higher for repeated procedures. During the median (IQR) follow-up of 403.0 (152.0-787.0) days from the index procedure, 80.0% of the patients died. CONCLUSIONS: Acute hemodynamic results of reBAV are comparable to those achieved during index BAV. However, reBAV may carry an increased risk of complications. Moreover, mortality is high due to unfavorable risk profiles or delays in receiving definitive therapy.


Assuntos
Estenose da Valva Aórtica , Valvuloplastia com Balão , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Estenose da Valva Aórtica/cirurgia , Valvuloplastia com Balão/efeitos adversos , Valvuloplastia com Balão/métodos , Valvuloplastia com Balão/estatística & dados numéricos , Insuficiência Cardíaca , Polônia , Resultado do Tratamento
18.
Expert Rev Cardiovasc Ther ; 20(12): 929-932, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36421070

RESUMO

BACKGROUND: As Percutaneous mitral balloon valvotomy (PMBV) remains the keystone in treating mitral stenosis, we conducted this review to elucidate the cumulative frequency and predictors of complications following PMBV and their occurrence in various patient populations. AREAS COVERED: We searched digital databases for relevant studies covering complications of PMBV and retrieved articles using the Medical Subject Heading (MeSH) keywords. EXPERT OPINION: A total of 37 articles (8 RCTs, 7 nonrandomized clinical trials, 22 observational studies) were selected for qualitative analysis. A total of 11,803 patients undergoing PMBV among 37 studies were included, with a mean success rate of 84.54%. The most common complication was mitral regurgitation (8.2%) followed by an atrial septal defect (2.4%). Other relevant complications like stroke, pericardial tamponade, rupture of mitral leaflets, and conduction abnormalities were present in <1% of the patients.


Assuntos
Valvuloplastia com Balão , Procedimentos Cirúrgicos Cardíacos , Insuficiência da Valva Mitral , Estenose da Valva Mitral , Humanos , Valvuloplastia com Balão/efeitos adversos , Estenose da Valva Mitral/cirurgia , Estenose da Valva Mitral/etiologia , Procedimentos Cirúrgicos Cardíacos/efeitos adversos
19.
J Vet Cardiol ; 44: 48-56, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36370467

RESUMO

INTRODUCTION/OBJECTIVES: Pulmonary artery dissection is a rare complication following balloon valvuloplasty for pulmonic stenosis. We sought to report the rate of this complication in dogs and describe the demographic, clinical, procedural, and outcome data in affected dogs. ANIMALS, MATERIALS AND METHODS: Medical records at a single academic institution between 2002 and 2021 were reviewed for dogs with pulmonic stenosis treated by a balloon valvuloplasty. Dogs were included for evaluation if there was evidence of pulmonary artery dissection on echocardiography or necropsy following balloon valvuloplasty. The demographic, clinical, surgical, and follow-up information were then recorded. RESULTS: Six dogs were included from 210 balloon valvuloplasty procedures for pulmonic stenosis giving a 3.9% rate of pulmonary dissection. There was a variety of signalment, pulmonary valve morphologies, and balloon catheter types used in each dog. All dogs had severe pulmonic stenosis (median pressure gradient of 208 mmHg, range 94-220 mmHg) with 5/6 dogs having a pressure gradient >144 mmHg. The median balloon to pulmonary valve annulus ratio was 1.35 (range 1.25-1.5). Three dogs died perioperatively, and three dogs were alive at follow up 3.3, 4.0, and 4.1 years postoperatively. CONCLUSION: Pulmonary artery dissection is a rare complication following balloon valvuloplasty for pulmonic stenosis. Extreme elevations in preoperative pulmonary valve flow velocity were common. Prognosis is variable, with a potential 50% perioperative survival rate, but extended survival times were noted in those patients discharged from hospital.


Assuntos
Dissecção Aórtica , Valvuloplastia com Balão , Doenças do Cão , Estenose da Valva Pulmonar , Cães , Animais , Valvuloplastia com Balão/efeitos adversos , Valvuloplastia com Balão/veterinária , Valvuloplastia com Balão/métodos , Artéria Pulmonar , Doenças do Cão/etiologia , Doenças do Cão/terapia , Estenose da Valva Pulmonar/etiologia , Estenose da Valva Pulmonar/terapia , Estenose da Valva Pulmonar/veterinária , Ecocardiografia/veterinária , Dissecção Aórtica/etiologia , Dissecção Aórtica/terapia , Dissecção Aórtica/veterinária , Resultado do Tratamento
20.
Methodist Debakey Cardiovasc J ; 18(1): 85-89, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36246498

RESUMO

Dual distal mini-balloon aortic valvuloplasty stabilized an 85-year-old patient with severe aortic stenosis. Puncturing both radial arteries solves the issue of large diameters at the aortic ring, introducing a feasible strategy in selected cases of fragile octogenarian patients with a high hemorrhagic risk. Moving at the anatomical snuffbox offers better postprocedural occlusion rates and better workspace ergonomics during the procedure.


Assuntos
Estenose da Valva Aórtica , Valvuloplastia com Balão , Procedimentos Cirúrgicos Cardíacos , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Valvuloplastia com Balão/efeitos adversos , Valvuloplastia com Balão/métodos , Humanos , Artéria Radial/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...